Alexander Marc Thomas successfully defended his PhD-Thesis – Congratulations!

Analysing the Impact of varying Environmental Conditions on a two-component Polyurethane Adhesive
Abstract:
Many industries are transitioning from mechanical fastening to adhesive bonding to improve performance and reduce costs. While many different adhesives are used, one of the most common is the polyurethane adhesive. With the adhesives being used in ever more critical components, a reliable quality control method is of ever greater importance. Current adhesive testing methods rely heavily on destructive techniques. These provide excellent insight into the mechanical properties and failure mode, but give little to no insight into the cause, as the underlying chemical processes are not examined. Differences in mechanical properties arise from a number of underlying chemical, physical, and/or mechanical mechanisms. For example, reduced tensile strength is often caused by changes in chemical composition due to altered environmental conditions during the curing process. These chemical differences should be detectable via non-destructive methods such as vibrational spectroscopy and in particular Fourier Transform Infrared Spectroscopy (FTIR).
This thesis demonstrates the possibility of correlating current destructive testing methods with vibrational spectroscopy and is studied on a two-component polyurethane adhesive. This would open the door for future research to allow for in-line quality control (QC) of the cohesive stability on real components. However, first, the mechanical impact of altered curing conditions must be studied independently of the underlying chemical changes. To this end, the adhesive was cured under twelve combinations of temperature and relative humidity and then tested using three realistic curing and testing procedures via the Single Lap Joint (SLJ) experiments. The adhesive was found to be highly sensitive to changes in testing conditions, with a reduction in tensile strength of about 45 % observed at the highest testing temperature (80 °C) and relative humidity (75 %). Samples cured under harsh conditions performed worse than those cured under ambient conditions. This could be explained by increased side reactions with urea rather than urethane. With the mechanical impact measured, the chemical differences causing these were studied using FTIR. Applying the first derivative of the spectra, the variations in chemical bonding with a shift towards urea from urethane at higher relative humidities could be clearly detected. This allowed spatial separation of the samples based on their curing conditions via principal component analysis (PCA), with individual clusters observed for each curing condition. Experiments were then performed to test if the conditions under which adhesives were cured could be retroactively determined once fully cured using partial least squares discriminant analysis (PLS-DA). High prediction accuracies were achieved for both conditions present in the training data and for conditions that were not.


