Aoife Canavan successfully defended her PhD-Thesis-Congratulations!




From Compound- to Fragment-Specific Stable Isotope Analysis: Spearheading Advances with Orbitrap Mass Spectrometry to Study Transformation of the Antimicrobial Sulfamethoxazole
Abstract:
The ongoing release of antimicrobials from livestock farming, agriculture, and wastewater treatment into the environment is a growing concern. Among these are synthetic sulfonamide antibiotics, which often do not fully degrade and can pose the risk of fostering antimicrobial resistance even at low residual concentrations. Sulfamethoxazole (SMX) is a prime example, as it is frequently detected in both aquatic and terrestrial environments. Therefore, understanding its behavior, fate, and transformation in the environment is crucial. However, this remains challenging, since conventional concentration measurements often fail to distinguish degradation from processes such as sorption or dilution. Here, analysis of the stable isotope ratio (e.g., 13C/12C) of the target antimicrobial is a complementary approach, known as compound-specific stable isotope analysis (CSIA). Such isotope ratios can differ between manufacturers, and they change during transformation processes due to kinetic isotope effects associated with specific transformation reactions. Conventionally, compound-average isotopic signatures are measured using gas chromatography hyphenated to isotope ratio mass spectrometry (GC-IRMS). Recently, Orbitrap mass spectrometry (Orbitrap-MS) has emerged as an alternative approach that even has the potential to access isotope information in specific molecular sites or fragments of the target compound. Therefore, the thesis specifically aimed to develop, first, a method for nitrogen stable isotope analysis of SMX by conventional GC-IRMS; to explore, second, stable carbon and nitrogen isotope fractionation analyzed by GC-IRMS during the reductive and oxidative transformation of SMX; to advance, third, stable isotope analysis by Orbitrap-MS through online coupling of liquid chromatography (LC) to Orbitrap-MS using SMX as a model analyte, and to prepare, fourth, compound-specific reference standards of SMX to enable fragment-specific carbon and nitrogen isotope analysis by Orbitrap-MS.
In the first research chapter, stable isotope analysis of SMX by GC-IRMS was extended to an additional element, nitrogen, since, until then, only carbon isotope analysis had been accessible. Nitrogen stable isotope analysis was enabled by combining a derivatization reaction of SMX with subsequent GC-IRMS measurements (derivatization-GC-IRMS). Here, SMX served as a model compound for sulfonamide antimicrobials to develop and refine the derivatization reaction with trimethylsilyldiazomethane as the derivatization reagent. Using the optimized derivatization conditions, precise and true nitrogen isotope analysis of SMX was accomplished across two labs, with a detection limit of 3 nmol N on column, equivalent to 0.253 μg of non-derivatized SMX. The versatility of the method was demonstrated by its applicability to four other sulfonamides, including sulfadiazine, sulfadimethoxine, sulfadimidine, and sulfathiazole. A preliminary application showcased the technique’s ability to differentiate SMX from various suppliers and pharmaceutical brands based on their nitrogen isotope signatures.
In the second research chapter, stable carbon and nitrogen isotope fractionation during the reductive and oxidative transformations of SMX was examined by naturally occurring minerals – Fe(II)-amended goethite and MnO2 suspensions – as model reactions for abiotic reductive and oxidative transformation, respectively. Reduction by surface-bound Fe(II) led to significant carbon isotope fractionation (εC = −3.6‰ ± 0.1‰ / εC = −2.9‰ ± 0.2‰, with and without buffer, respectively), and notable nitrogen isotope fractionation εN = −12.8‰ ± 0.6‰ and εN = −13.0‰ ± 0.2‰, with and without buffer, respectively). During reductive transformation, the detected transformation products were consistent with an initial reductive N-O bond cleavage. In turn, transformation with MnO2 caused normal carbon, but inverse nitrogen isotope fractionation (εC = −1.7‰ ± 0.1‰ / εC = −2.7‰ ± 0.2‰, with and without buffer, respectively, εN = +1.9‰ ± 0.2‰ without buffer), indicating an initial oxidative electron transfer. In contrast to the reductive transformation, transformation products of the oxidative transformation were not easily identified by high-resolution mass spectrometry, underscoring the value of compound- specific isotope analysis as an alternative for detecting ongoing transformation.
In the third research chapter, the online coupling of LC to Orbitrap-MS for stable isotope analysis was developed with SMX as a model compound – prior to this work, such hyphenation had only been realized with pure solutions of the target analytes. Because real-time coupling of LC to Orbitrap-MS would not allow for sufficiently long integration times, this study examined the fidelity of isotope measurements using two methods to capture and broaden LC peaks for subsequent precise isotope analysis. When collecting the target analyte in a capillary, the peak shape was maintained in the total ion count, and systematic deviations in the isotope ratio occurred due to chromatographic artifacts and amount-dependency in three fragments of SMX (aniline part (m/z = 92, F92), the SO2-group (m/z = 64, F64), and the 3-amino-5-methylisoxazole ring (m/z = 99, F99)). In turn, a dynamic mixing chamber enabled homogenization of the captured analyte, removed these artifacts, and enabled precise mass ratio measurements of carbon, nitrogen, and sulfur isotopologues across the three studied fragments of SMX as an average over the captured chromatographic peak. This setup was successfully calibrated for carbon and sulfur isotope ratios by comparing the isotope values with those measured by conventional IRMS techniques, resulting in a precision of 1.5‰ for F99 and 0.9‰ for F92 (95% Confidence Intervals based on uncertainties from n = 4 samples and n = 5 references).
In the fourth research chapter, compound-specific reference standards were synthesized for SMX to enable calibration of fragment-specific carbon and nitrogen isotope ratios by Orbitrap-MS. Fragmentation in the collision cell of the Orbitrap-MS resulted in two key fragments: F92 and F99. For these two fragments, reference materials were prepared by synthesizing SMX from specifically 13C- and 15N-labeled precursors and mixing labeled SMX with unlabeled SMX at natural abundance, resulting in a set of in-house standards with different isotopic signatures in carbon and nitrogen at specific positions of SMX. The isotope ratios of these in-house standards were measured by elemental analysis IRMS. Direct injection of standards into the Orbitrap-MS yielded a precision of 0.7‰ and 3.4‰ for carbon and nitrogen isotope analysis in F92, and 1.3‰ and 2.9‰ for carbon and nitrogen isotope analysis in F99 (95% Confidence Intervals based on uncertainties from n = 5 samples and n = 6 references). These reference materials enabled quantification of changes in fragment-specific carbon and nitrogen isotope ratios during reductive SMX transformation.
In conclusion, the work of this thesis underscores the added value of stable isotope analysis for studying the origin and fate of micropollutants, using SMX as a representative compound. The advancement of derivatization-GC-IRMS for nitrogen stable isotope analysis was an enabler for dual-element isotope analysis to decipher putative transformation pathways of SMX. Significantly different trends for reductive and oxidative transformation highlight the potential of CSIA to detect transformations in settings where concentration and transformation product analysis would be inconclusive. In parallel, this thesis’s advances in Orbitrap-MS are expected to be an enabler not only for micropollutant studies but for future compound- and position-specific stable isotope analysis across multiple scientific fields. For SMX, together with the prepared reference standards, this advance has paved the path for future studies to measure fragment specific stable isotope ratios during SMX transformation, as already demonstrated for a first application example. Together, this will contribute to a more comprehensive understanding of the environmental chemistry of SMX.